Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acad Emerg Med ; 29(12): 1431-1437, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36200372

RESUMO

INTRODUCTION: As frailty among the elderly is receiving increasing attention in emergency departments (EDs) around the world, the use of frailty assessment tools is growing. An often used such tool is the Clinical Frailty Scale (CFS), whose inter-rater reliability has been sparingly investigated in ED settings. No inter-rater reliability study regarding CFS has previously been performed within the Scandinavian ED context. The primary aim of this study was to evaluate the inter-rater reliability of the CFS in a Swedish ED setting. METHODS: This was a prospective observational study conducted at three Swedish EDs. Patients ≥65 years were independently assessed with CFS by their responsible physician, registered nurse, and assistant nurse. Demographic information for each assessor was collected, along with frailty status (frail/not frail) on the basis of clinical judgment. Inter-rater reliability was calculated using intraclass correlation coefficient (ICC), whereas agreement of frailty assessed by CFS (dichotomized between frail/not frail, cutoff at ≥5 points) versus solely by clinical judgment was calculated by using cross-tabulation. RESULTS: One-hundred patients were included. We found inter-rater reliability to be moderate to good (ICC 0.78, 95% confidence interval [CI] 0.72-0.84), regardless of whether the care team included an emergency physician (ICC 0.74, 95% CI 0.62-0.83) or an intern/resident from another specialty (ICC 0.83, 95% CI 0.74-0.89). The agreement of clinically judged frailty compared to frailty according to CFS was 84%. In the opposing cases, staff tended to assess patients as frail to a higher extent using clinical judgment than by applying CFS on the same patient. CONCLUSIONS: The CFS appears to have a moderate to good inter-rater reliability when used in a clinical ED setting. When guiding clinical decisions, we advise that the CFS score should be discussed within the team. Further research needs to be performed on the accuracy of clinical judgment to identify frailty in ED patients.


Assuntos
Fragilidade , Humanos , Idoso , Reprodutibilidade dos Testes , Fragilidade/diagnóstico , Serviço Hospitalar de Emergência , Estudos Prospectivos , Avaliação Geriátrica , Idoso Fragilizado
2.
J Biophotonics ; 11(6): e201700371, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29384267

RESUMO

OBJECTIVE: To describe the effect of low ambient temperature on skin temperature and capillary refill (CR) time in forehead, sternum and finger pulp. METHODS: An observational, nonrandomized experimental study on 15 healthy subjects (6 females) in a cold room (8°C). Outcome measures were skin temperature and quantified CR test after application of a standardized blanching pressure (9 N/cm2 ) using digital photographic polarization spectroscopy to generate CR times. RESULTS: The finger pulp showed marked temperature fall and prolonged CR times (>10 seconds). The CR registrations of the forehead and sternum were more comparable to curves observed in a control material at room temperature, and skin temperature falls were less marked. CR times were not prolonged in forehead measurements. At the sternum, some individuals showed CR times beyond guideline recommendations despite only a marginal reduction in skin temperature. CONCLUSIONS: Low ambient temperature is a strong independent factor for CR time at peripheral sites. Reservation about sternum as a site of measurement is warranted since cold provocation produced prolonged CR times in some individuals. We found that the forehead is the most thermostable of the 3 sites and thus the preferred site to avoid ambient temperature artifact in measuring CR time.


Assuntos
Capilares/fisiologia , Temperatura Cutânea , Temperatura , Adulto , Idoso , Feminino , Dedos/irrigação sanguínea , Testa/irrigação sanguínea , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Esterno/irrigação sanguínea
3.
J Biophotonics ; 11(1)2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28544641

RESUMO

To use Bioengineering methodology is used to achieve, at five anatomical sites, a detailed, quantitative assessment of the return of blood content to the blanched area, during the Capillary Refill (CR) test. An observational, non-randomized, experimental study on 23 healthy subjects (14 females) was performed in our climate controlled skin physiology laboratory. Our main outcome measures were based on the chronological assessment and quantification of red blood cell concentration (RBC) after the release of blanching pressure in the CR test, using Tissue Viability Imaging (TiVi), a digital photographic technique based on polarisation spectroscopy. TiVi enabled collection of detailed data on skin RBC concentration during the CR test. The results were shown as curves with skin blood concentration (TiVi-value) on the y-axis and the time on the x-axis. Quantitative CR responses showed site and temperature variability. We also suggest possible objective endpoint values from the capillary refill curve. Detailed data on skin RBC concentration during the CR test is easily obtained and allows objective determination of end points not possible to achieve by naked eye assessment. These findings have the potential to place the utility of the CR test in a clinical setting in a new light. Picture: Regular photograph and TiVi Image showing CR test and corresponding graph for the CR response.


Assuntos
Circulação Sanguínea , Análise Espectral/métodos , Adulto , Estado Terminal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...